Module Power up to 605W
Module Efficiency up to 23.4%

Bifacial Dual Glass Module

Lower LCOE & system cost

Excellent Anti-LeTID &
Anti-PID performance

Lower Power Degradation
Higher Energy Yield

Safety Protection Level Class Ⅱ
Engineering Drawings
Specifications (STC)
Maximum Power (Pmax-W) |
580 | 585 | 590 | 595 | 600 | 605 |
Power Tolerance | 0~+5 | |||||
Maximum Power Voltage (Vmp-V) |
43.88 | 44.02 | 44.17 | 44.31 | 44.45 | 44.59 |
Maximum Power Current (Vmp-V) |
13.22 | 13.29 | 13.36 | 13.43 | 13.50 | 13.57 |
Open-circuit Voltage (Voc-V) |
52.50 | 52.70 | 52.90 | 53.10 | 53.30 | 53.50 |
Short-circuit Current (Isc-A) |
13.95 | 14.01 | 14.07 | 14.13 | 14.19 | 14.25 |
Module Efficiency (%) |
22.50 | 22.70 | 22.80 | 23.00 | 23.20 | 23.40 |
STC:AM=1.5, irradiance=1000W/m2, cell temperature 25℃ |
Specifications (NMOT)
Maximum Power (Pmax-W) |
437 | 441 | 445 | 448 | 452 | 456 |
Maximum Power Voltage (Vmp-V) |
40.89 | 41.05 | 41.21 | 41.36 | 41.52 | 41.68 |
Maximum Power Current (Vmp-V) |
10.69 | 10.74 | 10.79 | 10.84 | 10.89 | 10.94 |
Open-circuit Voltage (Voc-V) |
49.37 | 50.06 | 50.25 | 50.44 | 50.63 | 50.82 |
Short-circuit Current (Isc-A) |
11.26 | 11.31 | 11.36 | 11.41 | 11.45 | 11.50 |
NMOT: irradiance 800W/m2, ambient temperature 20℃, wind speed 1m/s, AM 1.5 |
Temperature Characteristics
Nominal Module Operating Temperature | 42±2℃ |
Temperature Coefficient of Pmax | -0.29%/℃ |
Temperature Coefficient of Voc | -0.25%/℃ |
Temperature Coefficient of Isc | 0.045%/℃ |
Application Conditions
Maximum System Voltage | DC1500V(IEC) |
Maximum Series Fuse Rating | 30A |
Mechanical Loading | 5400Pa/2400Pa |
Hail impact experiment | Φ25mm hail, From 1m at speed of 23m/s |
Operating Temperature | -40℃~+85℃ |
Protection Class | Class II |
Bifaciality | 80±10% |
Related Products